Evaluation of the Effectiveness of Swimming Pool Position as a Tuned Liquid Damper in Reducing the Drift Rasio Due to Earthquake Excitation with Response Spectrum Analysis
DOI:
https://doi.org/10.32832/astonjadro.v14i2.17774Keywords:
tuned liquid damper; spring mass mode; swimming pool; sloshing;;passive control.Abstract
Swimming pools integrated with the main structure are increasingly popular in modern high-rise buildings due to their aesthetic appeal and recreational value. As a result, there has been much research into the influence of swimming pools, which were previously considered as additional masses, now function as passive dampers, Tuned Liquid Dampers (TLD). The focus of the research is the optimal placement of the swimming pool position because the swimming pool can increase the eccentricity to the center of mass, which affects the dynamic behavior of the building. This study analyzes the position of the swimming pool to affect the TLD's effectiveness in reducing the drift ratio. The study was conducted numerically with ETABS at a 10-story hotel with two basements and a total building height of 39.6 meters. The swimming pool measuring 16.25 x 4.85 x 1.5 meters was analyzed in empty conditions and two positions, namely Pool P1 (existing pool) with a mass eccentricity of 20.679 m. In contrast, pool P2 is a pool with a position that is moved closer to the center of mass, with a mass eccentricity of 10.650 m. The swimming pool is modeled with a spring-mass model as a dynamic load, and the damping ratio is 5%. The analysis used the mass spectrum response method based on SNI 1726:2019.
References
ACI-350. (2001). Seismic Design of Liquid -Containing Concrete Structures. ACI 350.3-01 – Code Requirements for Environmental Engineering Concrete Structures.
Badan Standarisasi Nasional. (2019). Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung. Bsn, 8, 254.
Banerji, P., Murudi, M., H. Shah, A., & Popplewell, N. (2000). Tuned Liquid Dampers for Control of Earthquake Response. 13th World Conference on Earthquake Engineering, August 1999, 587–602.
Bhujel, A., Bhatt, M. R., & Pradhan, P. M. (2023). Study of Seismic Effect on Reinforced Concrete Building Due to Swimming Pool on Roof Top. In Mechanisms and Machine Science: Vol. 125 MMS. Springer International Publishing. https://doi.org/10.1007/978-3-031-15758-5_126
Bikram, R. A., Bista, S., & Sunagar, P. (2018). IRJET-Analysis of Tuned Liquid Damper (TLD) in Controlling Earthquake Response of a Building using SAP2000 Analysis of Tuned Liquid Damper (TLD) in Controlling Earthquake Response of a Building using SAP2000. Certified Journal, 9001, 79–96. www.irjet.net
Davidson, S. S., & Kumar, A. S. (2018). Study on the Effect of Swimming Pool as Tuned Mass Damper. International Journal of Engineering Research & Technology (IJERT), 6(06), 1–5.
Housner, G. W. (1963). The dynamic behavior of water tanks. Bulletin of the Seismological Society of America, 53(2), 381–387. https://doi.org/10.1785/bssa0530020381
Ishak, I. S., Hamid, N. A., & Amin, N. M. (2021). Numerical Study on Various Position of Multiple Water Tanks toward Earthquake on High-rise Building. IOP Conference Series: Materials Science and Engineering, 1062(1). https://doi.org/10.1088/1757-899X/1062/1/012033
Li, X., Yin, X., & Zhang, H. (2011). Seismic response analysis of different plane structure in horizontal direction. Applied Mechanics and Materials, 90–93, 2487–2491. https://doi.org/10.4028/www.scientific.net/AMM.90-93.2487
Matsagar, V. (2015). Hydrodynamic Effects on a Ground Supported Structure. Advances in Structural Engineering: Dynamics, Volume Two, 751–1616. https://doi.org/10.1007/978-81-322-2193-7
Nanda, B. (2010). Application of tuned liquid damper for controlling structural vibration.
Palit, H. I., Ointu, B. M. M., & Windah, R. S. (2019). Analisa Bangunan Bertingkat Dengan Kolam Renang Akibat Gempa. Jurnal Sipil Statik, 7(6), 743–748. https://ejournal.unsrat.ac.id/index.php/jss/article/view/24070
Saputra, E. N., & Priastiwi, Y. A. (2023). Comparative Study Of Dynamic Earthquake Analysis With Spectral Design And Time History Methods. Jurnal Indonesia Sosial Teknologi, 4(8), 1223–1234. https://doi.org/10.59141/jist.v4i8.700
Seleemah, A. A., & El-Sharkawy, M. (2011). Seismic analysis and modeling of isolated elevated liquid storage tanks. Earthquake and Structures, 2(4), 397–412. https://doi.org/10.12989/eas.2011.2.4.397
Sorkhabi, A. A., Qiu, B., & Mercan, O. (2024). Investigating Large-Scale Tuned Liquid Dampers through Real-Time Hybrid Simulations.
Suja, G., & Subha, K. (2016). Sloshing Behaviour of Water in Water Tanks and Swimming Pools Subjected to Earthquake. International Journal of Scientific & Engineering Research, 7(10), 43–47.
Tejas, H. K., & Srinivas, K. S. (2022). A Study on Behavior of RCC Building with Tuned Mass Dampers and Stiffness Irregularities. 6–11.
Widyarsana, I. M. W., Damanhuri, E., Ulhusna, N., & Agustina, E. (2020). A Preliminary Study : Identification of Stream Waste Quantity and Composition in Bali Province , Indonesia. 5.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 ASTONJADRO

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Paper submitted to ASTONJADRO is the sole property of the Astonjadro Journal. Unless the author withdraws the paper because he does not want to be published in this journal. The publication rights are in the journal Astonjadro.ASTONJADRO
LICENSE
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Based on a work at http://ejournal.uika-bogor.ac.id/index.php/ASTONJADRO