ANALISIS KAPASITAS DAN KEKUATAN KONSTRUKSI BLADDER TANK PADA SIRKULASI AIR PANAS SISTEM ORC SOLAR KOLEKTOR R-134a

Authors

  • Irsan Novianto Universitas Ibn Khaldun
  • Yogi Sirodz Gaos Universitas Ibn Khaldun
  • Hablinur Alkindi Universitas Ibn Khaldun

DOI:

https://doi.org/10.32832/ame.v4i2.1536

Abstract

This study focused on component in the Organic Rankine Cycle (ORC), Bladder Tank. The calculation
method is based on the calculation stage of plate thickness to withstand the pressure caused by the
circulation of the ORC system. The material used is SA 106 with 12mm thickness, Shell length 600mm,
270mm inner diameter and 95mm Head length. From the calculation results obtained maximum
pressure on Shell = 253,8385 psi (17,7 bar g) and pressure at Head equal to = 249,6983 psi (17,2 bar
g). Bladder Tank Capacity of 38055622,5 mm³ (38,0556 Liter). From result of Pressure Drop simulation
got Head loss equal to = 0,00000066 m.

References

E. Bou Lawz Ksayera. 2011. Design of an

ORC system operating with solar heat and

producing sanitary hot water, Elsevier,

Volume 6 : pp 389-395, Paris.

Putra, Riki Candra. 2017. Perancangan

Bejana Tekan Kapasitas 5 M3 Dengan

Tekanan Desain 10 Bar Berdasarkan

Standar ASME 2007 Section VIII DIV 1.

Tangerang: Jurnal Teknik. 2-7.

White, Frank.M. (1986). Fluid Mechanics

Fourth Edition, McGraw-Hill, University Of

Rhode Island.

Verlag Europa-Lehrmittel. 1997.

Tabellenbuch metall. Nourney, Vollmer

Gmbh & Co.

Effendi, Riki. 2014. Optimasi Kekuatan

Horizintal Vessel Menggunakan Analisis

Elemen Hingga. Jakarta: Seminar Nasional

Sains dan Teknologi 2014.

4

Aziz, A., Hamid, A., & Hidayat, I. 2014.

Perancangan Bejana Tekan (Pressure

Vessel) Untuk Separasi 3 Fasa. Jakarta:

SINERGI Vol. 18, No 1.

Lloyd E. Brownell and Edwin H. Young.1959.

Equipment Design

Eugene F. Megyesy.1998. Pressure Vessel

Handbook. Pressure Vessel Handbook

publishing.USA

ASME Boiler and Pressure Vessel code,

section VIII div 1.2010, Rules for

Construction of Pressure Vessel, July 1,

Downloads

Published

2018-07-01

How to Cite

Novianto, I., Gaos, Y. S., & Alkindi, H. (2018). ANALISIS KAPASITAS DAN KEKUATAN KONSTRUKSI BLADDER TANK PADA SIRKULASI AIR PANAS SISTEM ORC SOLAR KOLEKTOR R-134a. AME (Aplikasi Mekanika Dan Energi): Jurnal Ilmiah Teknik Mesin, 4(2), 56–64. https://doi.org/10.32832/ame.v4i2.1536

Issue

Section

Articles