Analisis Daya Dukung Tiang Pancang Tunggal Berdasarkan Data NSPT yang Diverifikasi dengan Data SLT pada Proyek Gedung SIG 2 Bogor

Authors

DOI:

https://doi.org/10.32832/komposit.v8i2.17431

Keywords:

Analisis kapasitas dukung, verifikasi, NSPT, SLT (Static Loading Test)

Abstract

The foundation structure design for the construction of the SIG-2 Building uses a circular pile foundation with a diameter of 0.60 meters and a depth of 15 meters. Verification of the planned bearing capacity was carried out based on data from 2 (two) NSPT test points and continued by comparing the actual carrying capacity based on Static Loading Test (SLT) data. This research aims to compare the planned bearing capacity with the actual bearing capacity during construction, and settlement occurred. Analysis of bearing capacity calculations was carried out based on NSPT data using the Meyerhoff method, while analysis of actual bearing capacity calculations based on SLT data used the Davisson method, Chin method, and Mazurkeiwich method. Based on research conducted at 2 (two) test points, the average bearing capacity of the pile is 185.99 tons, and the average settlement (Sav) is 47.3 millimeters. The allowable settlement is 60 millimeters. The settlement on tested piles is 14,8 mm and 15,8 mm respectively. The results of the bearing capacity analysis based on actual Static Loading Test (SLT) data with a planned load of 200 tons using the Davisson method, Mazurkeiwich method, and Chin method are 179 tons, 185 tons, and 234,9 tons, respectively. Based on the upper structure loading data obtained from the structural planning report, it is concluded that the bearing capacity of the pile group is still safe and able to withstand the planned load on each column of the building structure, assuming the bearing capacity of a single pile of 179 tons, a total of 61 piles with the allowable bearing capacity of all piles of 10,809.81 tons and the building plan load of 9,066.23 tons.

 

References

Anugerah Hatatah Indah. (2019). Denah Tiang Pancang Perluasan Kantor SIG Bogor (p. 101).

Das, B. M. (2007). Principles of Foundation Engineering (7th, SI ed.). Cengage Learning.

Fadilah, U. N., & Tunafiah, H. (2018). Analisa Daya Dukung Pondasi Bored Pile Berdasarkan Data N-SPT Menurut Rumus Reese & Wright dan Penurunan. IKRA-ITH Teknologi Jurnal Sains Dan Teknologi, 2(3), 7–13. https://journals.upi-yai.ac.id/index.php/ikraith-teknologi/article/view/326

Ginting, S. V. N. B., Irwan, I., & Nurmaidah, N. (2019). Analisa Perhitungan Daya Dukung Pondasi Tiang Pancang Overpass Sei Semayang Sta. 0+350 pada Proyek Pembangunan Jalan Tol Medan-Binjai. Journal of Civil Engineering, Building and Transportation, 3(1), 40. https://doi.org/10.31289/jcebt.v3i1.2460

Harasid, H., Roesyanto, R., Iskandar, R., & Silalahi, S. A. (2018). An Analysis of the Static Load Test on Single Square Pile of 40x40 cm2, Using Finite Element Method in Rusunawa Project, Jatinegara, Jakarta. IOP Conference Series: Earth and Environmental Science, 126(1). https://doi.org/10.1088/1755-1315/126/1/012044

Lim, A. (2014). Evaluasi Formula Penentuan Daya Dukung Aksial Tiang Pancang Tunggal Menggunakan Data CPT Berdasarkan Metode Langsung (Direct Method). Research Report - Engineering Science, 2. https://journal.unpar.ac.id/index.php/rekayasa/article/view/1095

Mishra, A., Sawant, V. A., & Deshmukh, V. B. (2019). Prediction of Pile Capacity of Socketed Piles Using Different Approaches. Geotechnical and Geological Engineering, 37(6), 5219–5230. https://doi.org/10.1007/s10706-019-00976-0

Momeni, E., Maizir, H., Gofar, N., & Nazir, R. (2013). Comparative Study on Prediction of Axial Bearing Capacity of Driven Piles in Granular Materials. Jurnal Teknologi (Sciences and Engineering), 61(3), 15–20. https://doi.org/10.11113/jt.v61.1777

Muliati, T., Rahardjo, P. P., Anggoro, B. W., & Setiawan, R. (2022). The analysis of pile-pile cap behavior under static loading test using distributed fiber optic sensor. Indonesian Geotechnical Journal, 1(1), 41–57. https://doi.org/10.56144/IGJ.V1I1.7

Nurmaidah, N. (2017). Studi Analisis Perilaku Daya Dukung Pondasi Tiang Bor dengan Menggunakan Uji Beban Statik dan Model Tanah Mohr Coulomb Pada Proyek Paragon Square Tangerang, Banten. Educational Building: Jurnal Pendidikan Teknik Bangunan Dan Sipil, 3(1), 33–39. https://doi.org/https://doi.org/10.24114/eb.v3i1.7441

Prama, H., Purwana, Y. M., Djarwanti, N., Muslih, Y., Djarwanti, N., Purwana, Y. M., & Djarwanti, N. (2015). Perbandingan Analisis Kapasitas Dukung Tiang Tunggal Pondasi Minipile Menggunakan Rumus Dinamik, Hasil Uji SPT dengan Hasil Uji PDA. E-Jurnal Matriks Teknik Sipil, 3(2), 570. https://doi.org/10.20961/mateksi.V3I2.37215

PT. Sarana Data Persada. (2017). Laporan Pengujian Tanah Project Pembangunan Gedung SIG-2 Bogor.

PT. Teno Tract Indonesia Raya. (2019). Static Load Test Report Project Pembangunan Gedung SIG-2 Bogor (Vol. 1).

Putra, H., & Hidayat, C. (2014). Perbandingan Nilai Daya Dukung Ultimit Tiang Tunggal Berdasarkan Hasil Pengujian Beban Dinamik dan Statik. Jurnal Jalan-Jembatan, 31(3), 162–173.

Rahman, A. A., Hariati, F., Chayati, N., & Taqwa, F. M. L. (2020). Korelasi Hasil Analisis Daya Dukung Ultimit Tiang Bor dengan Hasil Pengujian PDA (Studi kasus: Pembangunan Jalan Tol Bogor Ring Road Seksi IIIA Simpang Yasmin - Simpang Salabenda). Jurnal Komposit: Jurnal Ilmu-Ilmu Teknik Sipil, 4(2), 43. https://doi.org/10.32832/komposit.v4i2.3468

Silitonga, A. P., & Iskandar, R. (2017). Perbandingan Daya Dukung Pondasi Tiang Pancang Metode Analitis dan Loading Test terhadap Metode Elemen Hingga Menggunakan Model Mohr-Coulomb dan Soft Soil pada Bore-Hole I (Studi Kasus Pembangunan Rusunawa Jatinegara Barat Jakarta Timur). Jurnal Teknik Sipil USU, 6(1). https://jurnal.usu.ac.id/index.php/jts/article/view/19433

Taqwa, F. M. L., Mardiaman, M., Hariati, F., & Muktadir, R. (2024). Rasio Daya Dukung Aksial Bored Pile Berdasarkan Hasil Uji SLT dan PDA (Studi Kasus: Tamansari Apartemen Bintaro Mansion Kota Tangerang Selatan). Prosiding TAU SNARS-TEK: Seminar Nasional Rekayasa Dan Teknologi, 3(1), 165–174. https://doi.org/10.47970/snarstek.V2I1.567

Taqwa, F. M. L., Muktadir, R., Hariati, F., Lutfi, M., & Apriliyandi, A. (2023). Studi Perbandingan Daya Dukung Aksial Tiang Pancang Tunggal Persegi Berdasarkan Hasil Uji Pembebanan Statik (SLT) dan Uji PDA pada Pembangunan Apartemen Loftville City Kota Tangerang Selatan. Jurnal Komposit: Jurnal Ilmu-Ilmu Teknik Sipil, 7(2), 129–138. https://doi.org/10.32832/komposit.v7i2.9176

Terzaghi, K., Peck, R. B., & Mesri, G. (2009). Soil Mechanics in Engineering Practice (3rd ed.). John Wiley & Sons, Inc.

Published

2024-08-01

How to Cite

Priyadi, W. J., Muktadir, R., Hariati, F., Taqwa , F. M. L., & Nandiasa, J. E. (2024). Analisis Daya Dukung Tiang Pancang Tunggal Berdasarkan Data NSPT yang Diverifikasi dengan Data SLT pada Proyek Gedung SIG 2 Bogor. Jurnal Komposit: Jurnal Ilmu-Ilmu Teknik Sipil, 8(2), 421–430. https://doi.org/10.32832/komposit.v8i2.17431

Issue

Section

Articles